Additional parameters

NCAction

<NCAction> element has one own parameters:

CLDArray

Type

Description

CmdPrm.Int[-1]

Integer

Probing cycle type: NCAction value = 1

CmdPrm.Int[-2]

Integer

SubCode of cycle specified in " SubCode for postprocessor " property on the <Job Assignment> tab

Custom properties

Custom properties have their own parameter codes that are stored in cycles and <NCAction> element:

CLDArray

Type

Description

CmdPrm.Int[-10]

Integer

Set WCS offset - mode. 0 - Global (all G54-G59); 1 - One WCS (one of G54-G59); 2 - Parametrical offset (G10 L2 P1 XYZ); 3 - Local CS offset (G52 XYZ)

CmdPrm.Int[-11]

Integer

Set WCS offset - CS Number ( Set WCS offset - mode = 1 or 2).

CmdPrm.Int[-12]

Integer

Set offset of tool number - Tool number

CmdPrm.Int[-13]

Integer

Set offset of tool number - Corrector 1

CmdPrm.Int[-14]

Integer

Set offset of tool number - Corrector 2

CmdPrm.Int[-15]

Integer

Check for broken tool - Tool number

CmdPrm.Int[-16]

Integer

Check for broken tool - Corrector 1

CmdPrm.Int[-17]

Integer

Check for broken tool - Corrector 2

CmdPrm.Int[-18]

Integer

Calibrate the tool probe number - Probe number

CmdPrm.Int[-19]

Integer

Calibrate the tool probe number - Corrector 1

CmdPrm.Int[-20]

Integer

Calibrate the tool probe number - Corrector 2

CmdPrm.Int[-21]

Integer

Calibrate the part probe number - Probe number

CmdPrm.Int[-22]

Integer

Calibrate the part probe number - Corrector 1

CmdPrm.Int[-23]

Integer

Calibrate the part probe number - Corrector 2

CmdPrm.Int[-24]

Integer

Write to report - Component number

CmdPrm.Int[-25]

Integer

Write to report - Feature number

For <Custom property> element, in <Job assignment> tab of probing cycle operation you manually set the code for the parameter to be stored in CLData and you can also set the type of the parameter. Custom parameter code must not be repeated with other codes.

images/download/attachments/128539926/image2022-4-6_0-30-4.png

Probe On/Off

The cycle on and off commands has parameters:

CLDArray

Type

Description

CmdPrm.Int[-1]

Integer

Probing cycle type: Cycle On/Off value = 0

CmdPrm.Int[-2]

Integer

Cycle On/Off SubCode = -500

CmdPrm.Bol[-3]

Boolean

On/Off mode. True is "On", false is "Off"