    COOLNT - Cooling

    Command caption

    How the command appears in the CLData command list:

    COOLNT ON(71)|OFF(72), N n
    

    COOLNT command turns on or off the machine cooling systems. The first parameter specifies command type: activation or deactivation. The second parameter is the tube number which is affected by the COOLNT command.

    Access from sppx

    Handler: program Coolnt

    Parameter CLD array CLD name Description
    ON(71)
    OFF(72)
    CLD[1] CLD.OnOff Command type: ON(71) – activate coolant, OFF(72) – deactivate coolant.
    n CLD[2] CLD.N Coolant tube number: 1 – flood, 2 – mist, 3 – tool.

    To create ISO postprocessor using masks use ISO.M values which correspond to parameters:

    CLD parameter ISO value
    CLD[1] = 71 ISO.M = 8
    CLD[1] = 72 ISO.M = 9

    Example (from the Fanuc (30i)_Mill postprocessor):

    program CoolNt
      if cld[1] = 71 then begin
        if cld[2] = 1 then begin
          Mc = 8
        end else if cld[2] = 2 then begin
          Mc = 8
        end else if cld[2] = 3 then begin
          Mc = 8
        end else begin
          Mc = 8
        end
      end else begin
        Mc = 9     ! On/Off coolant
        OutBlock
      end
    end
    

    Access from .NET

    Handler:

    public override void OnCoolant(ICLDCoolantCommand cmd, CLDArray cld)
    

    Inheritance: ICLDCoolantCommand : ICLDCommand.

    Read the parameters from the strongly-typed cmd object (recommended); the raw cld[i] array (same indices as in sppx) and the named cmd["..."] helpers are available too. The table lists the command's members, including those inherited from its base interfaces; the common ICLDCommand members (navigation, CLD, CLDFile, TechOperation, ...) are described in the CLData access model.

    Member Type Description
    cmd.IsOn bool Returns "True" if it's a switch on command and you need to switch ON all tubes marked in the TubeIsOn[] list.
    cmd.IsOff bool Returns "True" if it's a switch off command and you need to switch OFF all tubes marked in the TubeIsOn[] list.
    cmd.TubeCount int Returns the count of tubes presented in the TubeIsOn[] list.
    cmd.TubeIsOn ICLDCoolantTubeIndexer Allows you to determine whether or not to switch the state for the tube with a given index. The index must be between 0..31 (TubeCount-1).
    cmd.FirstEnabledTube int Returns the index of the first tube to be switched, i.e. TubeIsOn[FirstEnabledTube]=true.

    Example - OnCoolant (from the Fanuc (30i)_Mill_DN postprocessor):

    public override void OnCoolant(ICLDCoolantCommand cmd, CLDArray cld)
    {
        if (cmd.IsOn) {
            nc.MCoolant.v = 8;
        } else {
            nc.MCoolant.v = 9;
            nc.Block.Out();
        }
    }
    

    See also